Many ACT Science figures look complicated at first glance, so we need a clear way to read one value or trend without getting lost in everything else on the graph.
1
Crowded graphs and stacked panels
A crowded graph puts several curves (and sometimes a second vertical scale on the right) over one horizontal axis, while a stacked figure lines up separate panels one above another over a shared bottom axis. In both layouts, we want to read the measurement the question asks for without using the wrong scale.
Crowded graphs and stacked panels
In the three-panel plant figure, we want the stem growth at the temperature where water loss reaches 400 mL, and we want to know whether the stem or the roots grew more at that temperature.
Text solution
Find the shared temperature in the bottom panelStart at 400 mL on the Water Loss axis, move across to the curve, and drop straight down to the shared bottom axis.
Water Loss⟹Temperature=400 mL=30∘C
Follow 30∘C straight up to the stem panelFollow the 30∘C line straight up into the top panel until you hit the stem curve, then read the top panel's left axis.
Temperature⟹Stem Growth=30∘C=8 cm
Read each panel's own scale to compare growthStay on 30∘C in the middle panel and read its 0–50 cm axis rather than judging by how high the curve sits.
Root Growth>Stem Growth=20 cm=8 cm
So at 30∘C the stem grows 8 cm, and the roots grow more than twice as much (20 cm) even though the stem curve sits higher inside its panel.
2
Upside-down and multiplying scales
Sometimes an ordinary evenly spaced axis doesn't fit what is being measured: ocean depth starts at 0 m at the surface and increases downward, and fast-growing bacteria counts can jump from 10 to 10,000 in a few hours. To read values, trends, or ratios on these graphs, we follow how the numbers step along the axis rather than how steep or tall the curve looks.
Upside-down and multiplying scales
On the multiply-by-10 bacteria graph, we want the bacteria count at Hour 2 (where the curve sits on the second minor tick mark above 100) and how many times greater the count is at Hour 3 than at Hour 1.
Text solution
Count minor tick marks upward from the major line belowBetween 100 and 1,000, each minor tick mark adds 100, so we step up twice from 100 instead of guessing 550 just because the dot looks halfway up.
100+100200+100300 bacteria at Hour 2
Read both axis values before comparingRead the actual numbers off the vertical axis at Hour 1 and Hour 3 first, because each equal step up the major lines multiplies by 10.
So the dish holds 300 bacteria at Hour 2, and Hour 3 has 100 times as many bacteria as Hour 1 even though its dot sits only three blocks up instead of one.
Compare this with a standard 0-to-10,000 axis of the same height, where everything from 1 to 1,000 gets crowded right down near zero. On the multiply-by-10 axis, each equal vertical block multiplies the count by 10, opening up space for the smaller numbers and putting 300 near the middle of the gap between 100 and 1,000.
Each equal step up a multiply-by-10 axis multiplies the bacteria count by 10, spreading out small counts that stay crowded near zero on a standard scale.
3
Contour, circle, and triangle graphs
Some figures arrange their scales into curved map lines (contour plots), compass directions and rings (circle graphs), or a three-sided grid for mixtures that add up to 100% (triangle graphs). In each shape, our goal is to read a point's value from the scale lines it sits on or between.
Contour, circle, and triangle graphs
For the sample dot inside the Sand–Clay–Silt triangle, we want the percentage of each of the three ingredients.
Text solution
Count from the 0% Sand side toward the Sand cornerStart at the bottom side (opposite the top Sand corner) and count the horizontal grid lines straight up to the dot.
Sand=60%
Count from the 0% Clay side toward the Clay cornerStart at the left side (opposite the bottom-right Clay corner) and count the slanted grid lines toward the Clay corner until you reach the dot.
Clay=30%
Subtract from 100% for the third ingredientAll three ingredients in the mixture always add up to 100%.
Silt=100%−60%−30%=10%
So the dot represents a mixture of 60% sand, 30% clay, and 10% silt.
Every point in the triangle splits the mixture into three parts that add up to 100%: a corner is 100% of that ingredient, the entire side opposite that corner is 0%, and moving along a single grid line keeps one ingredient constant while changing the other two.
Anywhere on the triangle, Sand, Clay, and Silt fill the whole jar, and each one goes from 0% along one side to 100% at the corner across from it.
4
Apparatus diagrams
An apparatus diagram has no axes or data points at all. It is a map of pipes, chambers, sensors, and traps showing what happens in order along a flow path. Questions usually change one spot, like opening a valve or adding a crack in a pipe, and ask what reaches the end of the setup.
Apparatus diagrams
When room air carrying dust and water vapor leaks through a crack in the pipe between the Filter and the Drying Tube, we want to find which unwanted substance reaches the Heated Metal Chamber.
Text solution
Start at the leak and check what sits upstreamBecause the Filter is behind the crack, dust entering through the crack never passes through the Filter.
⟶Filter (traps dust)bypasses FilterCrack(dust + water vapor enter)
Follow the flow arrows downstream to the chamberCarry both leaking substances forward through the remaining parts of the setup to see what still gets caught.
⟶⟶CrackDrying Tube(removes water vapor)Chamber (dust only)
So only dust reaches the Heated Metal Chamber, because the Drying Tube is still ahead of the leak to catch the water vapor.
Whether a leak happens before the Filter, between the two traps, or past the Drying Tube, the rule is the same: a trap only removes substances that enter upstream of it. Anything that enters the pipe downstream of a trap bypasses it and keeps going into the chamber.
Each trap only catches what enters before it, so any dust or water vapor that leaks in past its trap goes straight into the chamber.
5
Reading one curve at a time
The busiest figures on the test combine an upside-down axis, two different scales, and four overlapping curves in a single frame. Even then, we only ever trace one curve at a time by matching the question's words to the axes and key before looking at the data.
Reading one curve at a time
For a single reading, like salinity at 400 m in Winter, match `Salinity` to the bottom axis (ppt) and `Salinity (Winter)` to the dashed black triangles first. That keeps us from reading 7.5 off the top Oxygen axis:
Now take a trend across the upside-down axis: how dissolved oxygen changes in Summer as depth increases from 0 m to 800 m. Tracing downward from 0 m to 800 m along `Oxygen (Summer)` (solid line with open circles) while watching the top axis gives:
Finally, suppose a question links two curves: "In Summer, at the depth where dissolved oxygen is lowest, what is the salinity?" That question breaks cleanly in half at the comma.
Text solution
First half: find the depth on the Summer oxygen curveFind the smallest top-axis value along the solid line with open circles, then look left to the Depth axis.
LowestSummerOxygen⟹Depth=2 mg/L=400 m
Second half: read Summer salinity at that same depthStay on the 400 m line, move across to the solid line with black triangles, and drop straight down to the bottom Salinity axis.
So in Summer, at the depth where dissolved oxygen is lowest, the salinity is 34.5 ppt.
Key concepts
Whenever you meet a crowded or unusual figure, read the labels and scales around the outside before looking at the curves inside. Match the measurement and unit in the question to its own axis and key entry first (`Salinity, Winter` → bottom ppt axis, dashed ▲) so you can ignore every other curve and scale. If a question links two curves or two stacked panels ("at the depth where dissolved oxygen is lowest, what is the salinity?"), break it at the comma: use the first curve to find the shared axis value (2 mg/L⟹400 m), then read the second curve there (34.5 ppt). When two curves share the exact same evenly spaced axis, higher on that axis really does mean greater. How high or steep a curve looks can mislead you when curves use different scales (0–10 cm vs. 0–50 cm), when an axis points downward (0 m at the top to 800 m at the bottom), or when equal steps multiply by 10(1,10,100,1,000). On that last scale, the second minor tick above 100 is 300 even though it sits near the middle of the gap, and two gridlines compare by their numbers (101,000=100 times). On unusual shapes, estimate halfway between neighboring contour lines (20 and 30⟹25), read direction around the rim and amount outward on a circle graph, and count grid steps from an ingredient's opposite 0% side toward its 100% corner on a triangle graph (60%+30%+10%=100%). And on an apparatus diagram with no scales at all, put your finger where the change happens and follow the arrows downstream, ignoring traps upstream that have already been passed.
6
Practice
1
Engineers tested two silicon solar panels, one with cooling fins on the back (finned) and one without fins (unfinned), at solar irradiance levels from 200 W/m2 to 1,000 W/m2. The results are shown in Figure 1.
According to Figure 1, at a solar irradiance of 800 W/m2, what is the panel temperature of the unfinned panel?
Check which vertical axis has units of ∘C and which line style and symbol in the key represent the unfinned panel's temperature before tracing up from 800 W/m2.
Match `Panel temperature` and `unfinned` to the key first: dashed line with solid triangles (picking the solid-line triangle curve for the finned panel instead gives A, 40∘C, and picking the dashed open-circle power curve and reading the left axis gives C, 220∘C). At 800 W/m2, the dashed solid-triangle curve sits at grid height 5.0. Look right to the `Panel temperature (°C)` axis to read 50∘C, rather than looking left out of habit to the `Power output` axis, which gives D(250∘C). B
2
Figure 1 shows a laboratory gas-purification setup that supplies pure argon (Ar) to a sealed glovebox.
Suppose Valve V accidentally opens while the system is running, letting raw argon from the backup tank into the main pipe. Which trace gas or gases will reach the sealed glovebox?
Put your finger where Valve V meets the main pipe and follow the flow arrow toward the glovebox. Which tubes sit behind that spot, and which tube still sits ahead of it?
Start at Valve V, between Tube 2 and Tube 3, and follow the flow arrow to the right toward the glovebox (mixing up the tubes and reading Tube 3 as the one that removes CO2 gives C, H2O vapor and O2 only). Tube 1 (removes CO2) and Tube 2 (removes H2O vapor) both sit upstream behind Valve V, so raw argon from the backup tank bypasses both of them (treating Tube 2 as if it still caught water vapor gives A, CO2 only). Downstream ahead of Valve V sits Tube 3, which removes O2 (listing the caught gas instead of the two that pass through gives B, O2 only), leaving CO2 and H2O vapor to reach the glovebox. D
3
Engineers measured water temperature at different depths in a salt-gradient solar pond during the afternoon (see Figure 1).
Based on Figure 1, as depth increases from 0.0 m to 3.0 m, water temperature:
Which direction on the left axis goes from 0.0 m to 3.0 m, and what happens to the numbers on the top temperature axis as you follow the curve that way?
Depth increases downward from 0.0 m at the top to 3.0 m at the bottom (tracing backward from 3.0 m up to 0.0 m gives D). From 0.0 m down to 1.5 m, watch the top axis numbers rather than the downward slant on the page (reading that downward slant as a decrease gives C): temperature rises from 35∘C to 80∘C. From 1.5 m down to 3.0 m, the curve drops straight down beneath 80∘C on the top axis, so temperature stays constant at 80∘C (mistaking a vertical drop for a temperature decrease gives B). A
4
Botanists grew Species M marsh grass for 6 weeks in nutrient solutions with dissolved phosphate concentrations of 0,2,4,6, and 8 mg/L (see Figure 1).
According to Figure 1, at the dissolved phosphate concentration where root oxygen release is greatest, leaf dry mass is how many times as great as flower bud dry mass?
Find the peak in the bottom panel first to identify the phosphate concentration, then read the gram scales on the two upper panels rather than comparing how high the curves sit.
In the bottom panel, `Root oxygen release` reaches its peak of 9 mg/hr at 6 mg/L dissolved phosphate (reading at the rightmost mark, 8 mg/L, gives 2.04.0=2,C). Follow 6 mg/L straight up and read each panel's gram scale instead of comparing how high the curves sit in their boxes (the leaf curve sits 30% up its box while the flower bud curve sits 75% up its box, so comparing visual heights gives 0.750.30=0.4,B): `Leaf dry mass` is 6.0 g and `Flower bud dry mass` is 1.5 g. Divide leaf dry mass by flower bud dry mass to get 1.56.0=4, not the reverse (6.01.5=0.25,A). D
5
Microbiologists exposed water samples containing Strain R bacteria to ultraviolet (UV) doses from 0 mJ/cm2 to 40 mJ/cm2 and measured the surviving bacteria concentration (see Figure 1).
Based on Figure 1, the surviving bacteria concentration at a UV dose of 10 mJ/cm2 is how many times as great as the surviving bacteria concentration at a UV dose of 30 mJ/cm2?
Count upward from the 1,000 line along the minor tick marks to read the concentration at 10 mJ/cm2 before dividing by the concentration at 30 mJ/cm2.
At 10 mJ/cm2, the curve sits on the 2nd minor tick mark above the 1,000 line, so count up from 1,000 by thousands: 1,000→2,000→3,000 cells/mL (starting the count from zero gives 2,000 and leads to B, 200, while treating the visual middle between 1,000 and 10,000 as a standard halfway value of 5,500 leads to D, 550). At 30 mJ/cm2, the curve sits on the 10 cells/mL line. Divide the axis readings rather than comparing block heights (3.5 blocks high vs. 1 block high gives A, 3.5): 103,000=300.C
6
Ceramic engineers measured the minimum vitrification temperature (∘C) required to fuse porcelain mixtures made of quartz, feldspar, and kaolin summing to 100% by mass (see Figure 1).
Based on Figure 1, what is the minimum vitrification temperature of a porcelain mixture composed of 20% quartz, 50% feldspar, and 30% kaolin?
Locate the mixture point by counting 2 grid steps up from the bottom 0% Quartz side and 5 grid steps from the left 0% Feldspar side, then see which two temperature contour lines it falls between.
Count 2 grid steps (20%) straight up from the bottom 0% Quartz side, and 5 grid steps (50%) from the left 0% Feldspar side toward the Feldspar corner, leaving 3 steps (30%) from the right 0% Kaolin side (swapping Quartz and Kaolin lands on the 1,200∘C line, B; swapping Feldspar and Kaolin lands halfway between 1,200∘C and 1,300∘C at 1,250∘C,C; miscounting 50% Quartz, 30% Feldspar, and 20% Kaolin lands on the 1,400∘C line, D). Along the 20% Quartz horizontal line, the 1,100∘C contour passes through (20% Quartz,60% Feldspar,20% Kaolin) and the 1,200∘C contour passes through (20% Quartz,40% Feldspar,40% Kaolin), so our mixture at 50% Feldspar sits halfway between those two lines at 1,150∘C (don't round to the 1,200∘C line, B). A
7
Oceanographers measured horizontal current speed and suspended sediment concentration from the surface (0 m) to the riverbed (20 m) at Station E in a tidal estuary at High Tide and Low Tide (see Figure 1).
According to Figure 1, at Low Tide, at the depth where current speed is lowest, what is the suspended sediment concentration?
Split the question at the comma: use the Low Tide current-speed curve first to find the depth, then move across at that depth to the Low Tide sediment curve and read the bottom axis.
First half: trace `Current speed, Low Tide` (dashed open circles), which reaches its lowest grid position (0.5, or 10 cm/s on the top axis) at a depth of 10 m (using the High Tide speed curve's lowest point at 20 m depth instead leads to grid position 3.8, or 190 mg/L,D). Second half: stay at 10 m depth and move across to `Suspended sediment, Low Tide` (dashed solid triangles) at grid position 2.5 (stopping on the solid High Tide sediment curve at 1.8 gives 90 mg/L,B). Drop straight down to the bottom `Suspended sediment (mg/L)` axis to get 125 mg/L, rather than looking up to the top `Current speed` axis, which reads 50 (A). C