Many ACT Science questions go beyond the trials already on the page, asking what will happen in a new trial or how the scientist should change the setup, even when the passage is full of unfamiliar lab terms.
Knobs, meters, and predicting
Strip away the technical labels and every experiment has knobs (what the scientist changes on purpose) and a meter (what gets measured). Predicting and redesigning run that same setup in opposite directions:
Predict: Redesign: knob⟶metermeter⟶knob
When a table includes more than one knob, cross out any row where the other knobs don't match the question (such as a saltwater trial mixed in with freshwater rows). And when a sentence in the passage adds a new factor, like sunlit green algae releasing oxygen into a 20 °C fish tank, write quick arrows from link to link rather than trusting words like "extra" or "more":
So adding sunlit algae pushes the fish's breathing rate below 45 breaths per minute.
In this 20 °C tank, brighter light on the green algae raises dissolved oxygen above 10. Because oxygen and breathing have an inverse relationship, that higher oxygen pulls the fish's breathing rate down below 45 breaths per minute.
In this 20 °C tank, brighter light on the algae pushes dissolved oxygen up, which slows the fish's breathing down.
1
Why a step is in the procedure
Before asking you to change an experiment, passages often point to one small detail in the procedure, such as waiting 15 minutes after moving a fish with a net, and ask why the scientist included it.
Why a step is in the procedure
Every precaution in a procedure keeps an outside factor from throwing off the meter or a locked knob. You can spot why it's there by picturing what happens if you leave that step out:
skip 15-min wait⟶panic from the net remains⟶meter reads fear alongside O2
2
Redesigning an experiment
Now suppose we want to change the setup itself: to test a brand-new knob, push the measurement toward a target value, fix trials that maxed out, or test the same relationship with a different tool.
Redesigning an experiment
Each redesign question works backward from what we need the meter to show:
Testing a new knob. Vary only the new knob while locking every other knob at one value, and include a "do-nothing" control trial alongside any added treatment. Watch out for neat-looking answer choices where a second knob changes right alongside the new one.
Hitting a target. Start at the meter reading you want and trace the arrows backward to see which way each knob should turn:
Fixing a setup that flattens out. When readings stop climbing (such as gas volumes flattening at 100 mL for 3, 4, and 5 g of baking soda), check what physically ran out: either the measuring tool filled up (use a larger tube or less baking soda) or an ingredient in the cup ran out (start with more vinegar).
Across these five baking-soda-and-vinegar cups (1 g to 5 g), 100 mL collection tubes overflow and cap Trials 3 to 5 at 100 mL. Switching to tubes larger than 140 mL stops the overflow and shows a second limit at 140 mL, where Cup 5 runs out of vinegar and leaves unreacted baking soda on the bottom.
Bigger gas tubes lift the readings where gas overflowed, while readings where the vinegar ran out stay flat no matter how big you make them.
Testing the same idea with a new meter. Keep the same knob and the same cause-and-effect question, then picture the setup physically to make sure the new meter actually responds when the effect happens.
In an open cup, escaping gas bubbles carry mass off the scale. A sealed cap traps all of that gas right on the scale so the mass never changes, which means a sealed bottle needs a pressure sensor instead.
3
Precision and accuracy
Sometimes a redesign fixes the quality of the measurements rather than changing what is tested. Precision is how tightly repeated readings cluster together, and accuracy is how close they land to the true value.
Precision and accuracy
true O2=10.0
In a test bottle with a true oxygen level of 10.0, those two flaws look different in the data and require different fixes:
precise, not accurate(built-in offset)7.1,7.2,7.1⟶zero or calibrate the tool,subtract empty cup, or insulate
not precise(random trial-to-trial wobble)5.4,12.9,8.1⟶use a steadier or finer-marked tool,or average several trials
In this 10.0 oxygen test bottle, averaging repeated dips of the shaky, zeroed gauge brings the result close to 10.0 because the high and low wobble cancels out. Meanwhile, the un-zeroed digital probe clusters tightly around 7.1 to 7.2 and stays nearly 3 units too low no matter how many trials you run.
Repeating trials cancels random wobble so the average gets close to the true value, but an un-zeroed sensor's average stays off by the same amount every time.
4
Working a full passage
Now let's put predicting and redesigning together on a table that uses unfamiliar chemistry terms.
Spectrophotometric absorbance at 450 nm of oxidized o-dianisidine catalyzed by Horseradish Peroxidase (HRP)
Trial
HRP (units)
Wait time (s)
Absorbance
1
2
30
0.20
2
4
30
0.40
3
8
30
0.75
4
4
60
0.70
Predict the absorbance if HRP is 6 units and Wait time is 30 s.
How should a student set up new trials to test whether temperature affects absorbance?
Suppose this machine displays an error whenever absorbance exceeds 1.00, and testing HRP at 12 units and 16 units for 30 s pushes both readings past 1.00. Without replacing the machine, how can the scientist redesign those trials to compare 12 units and 16 units?
Working a full passage
Trial
HRP(units)
Wait time(s)
Absorbance
?
?
?
Text solution
1. Match the 30 s wait time and place 6 between 4 and 8Cross out Trial 4 (where wait time jumped to 60 s) and read halfway between Trials 2 and 3 to find an absorbance of about 0.58:
Wait time=30 s:HRP 4HRP 8⟹HRP 6→0.40,→0.75≈0.58
2. Vary temperature alone while locking HRP and wait timeRun trials across several temperatures while holding both original knobs fixed so only temperature can shift absorbance:
3. Shorten wait time equally to pull both readings below 1.00Comparing Trial 4 (60 s → 0.70) with Trial 2 (30 s → 0.40) shows that shorter waits lower the absorbance, so measure both 12 units and 16 units at the same 10 s wait time:
Wait time 30 s→10 sfor both HRP 12 and 16⟹both readings<1.00(fair comparison)
Key concepts
Read past unfamiliar names by labeling the knobs (what the scientist changes) and the meter (what gets measured). When predicting (`knob → meter`), cross out trials where locked knobs don't match (ignore a saltwater row when predicting for freshwater), and write one arrow per link whenever the passage adds a new step to the chain (`sunlit algae → O₂ ↑ → breathing ↓`). When asked why a step is in the procedure, ask what breaks if it is skipped (no 15-minute wait leaves panic on the breathing meter). When redesigning (`meter → knob`), lock every other knob to isolate or fairly compare one factor (test both HRP 12 and HRP 16 at 10 s), but turn multiple knobs together when pushing the meter to an extreme (colder water plus sunlit algae for slowest breathing). If measurements flatten out, check whether the tool hit its limit (100 mL tube overflowing) or an ingredient ran out (vinegar used up); if swapping in a new meter, check that the new tool can physically detect the change (an open cup loses gas mass on a scale, whereas a sealed bottle traps it). Finally, cut random scatter (precision) with steadier tools or averaged trials, but don't just run extra trials on an off-center tool (`7.1, 7.2, 7.1` for `10.0`): zero or calibrate it to fix accuracy.
5
Practice
1
Students wrapped insulated copper wire around an iron nail connected to a battery and measured the maximum mass of steel paper clips the electromagnet could lift.
Table 1
Trial
Wire coils
Battery voltage (V)
Maximum mass lifted (g)
1
20
1.5
12
2
40
1.5
24
3
80
1.5
46
4
60
3.0
68
Based on Table 1, if the students tested an electromagnet with 60 wire coils connected to a 1.5 V battery, the maximum mass lifted would most likely be closest to:
Check the battery voltage column before looking for 60 wire coils: which trials match the 1.5 V battery?
Match the 1.5 V battery first. Don't grab Trial 4 just because it lists 60 wire coils, since Trial 4 used a 3.0 V battery (which eliminates D, the likeliest slip, as well as C, which averages Trial 3 at 1.5 V with Trial 4 at 3.0 V). Using only the 1.5 V trials, 60 coils sits halfway between Trial 2 (40 coils → 24 g) and Trial 3 (80 coils → 46 g), whereas A (18 g) misreads the rows and lands between 20 and 40 coils. Halfway between 24 g and 46 g is 35 g. Answer: B
2
To test how rock color affects solar heating, a student collected slabs of dark basalt, red sandstone, and white limestone of equal size from an outdoor quarry on a sunny afternoon. Before placing each slab under an indoor heat lamp for 10 minutes and recording its final surface temperature, the student left all three slabs on a wooden table in a shaded 21 °C room for 3 hours.
Why did the student leave all three rock slabs in the shaded 21 °C room for 3 hours before placing them under the heat lamp?
Picture skipping the 3-hour wait right after bringing dark and light rocks in from a sunny afternoon: what would be unequal before the heat lamp even turned on?
Coming in from a sunny quarry in the afternoon, dark basalt starts out warmer than white limestone. Skipping the 3-hour wait in the shaded 21 °C room would leave the slabs at different starting temperatures before the heat lamp even turned on. Watch out for B: cooling rocks in the shade does not change rock color or equalize the fraction of light they absorb (the very property being tested). C misreads when the step happens (resting beforehand does not insulate the slabs during the 10-minute lamp trial), and D invents a shade-warming test the student never ran. Answer: A
3
Scientists studied juvenile freshwater snails in 22 °C tanks in which dissolved oxygen was held constant. Aquatic moss placed under bright light absorbs dissolved CO₂ from water during photosynthesis.
In Experiment 1, scientists bubbled different amounts of CO₂ into water tanks and measured water pH.
Table 1
Dissolved CO₂ (mg/L)
Water pH
2
8.1
6
7.6
12
7.2
20
6.9
In Experiment 2, scientists placed snails for 30 days into moss-free tanks maintained at different pH levels and measured average shell mass gained.
Table 2
Water pH
Average shell mass gained (mg)
6.8
11
7.2
24
7.6
38
8.0
49
Without moss, snails in water containing 12 mg/L of dissolved CO₂ (pH 7.2) gain an average of 24 mg of shell mass in 30 days. In a new 30-day trial, snails are placed in water that initially contains 12 mg/L of dissolved CO₂ together with brightly lit aquatic moss in a tank sealed against outside CO₂ (with temperature and dissolved oxygen held constant). Based on the passage and tables, the average shell mass gained by these snails would most likely be:
Start with what the passage says sunlit moss does to dissolved CO₂, then write one arrow from Table 1 (CO₂ → pH) and one arrow from Table 2 (pH → shell mass gained).
Trace one arrow per link: brightly lit moss absorbs dissolved CO₂ (CO₂ ↓ below 12 mg/L, ruling out B and D, which misread the passage and say moss raises CO₂). In Table 1, watch the inverse relationship: as dissolved CO₂ drops from 12 toward 6 mg/L, water pH rises from 7.2 toward 7.6 (eliminating A, which flips that inverse trend and says lower CO₂ lowers pH). In Table 2, raising pH above 7.2 pushes average shell mass gained above 24 mg. Answer: C
4
An engineering student tested scale models of a wind turbine with 20 cm blades inside a wind tunnel and measured electrical power output.
Table 1
Trial
Number of blades
Blade angle (°)
Wind speed (m/s)
Power output (W)
1
3
15
4
1.2
2
3
15
6
4.0
3
3
15
8
9.4
Using 20 cm blades, which set of three new trials should the student run to determine how blade angle alone affects electrical power output?
Find the single knob the question asks to test, and check that the other two columns stay locked across Trials 4, 5, and 6.
To isolate blade angle, vary blade angle (10°, 20°, 30°) while locking blade count at 3 and wind speed at 6 m/s. Don't fall for A: it looks neat because wind speed goes up (4, 6, 8 m/s) just like in Table 1, but that changes wind speed and blade angle at the same time. B similarly changes blade count alongside blade angle, and C locks blade angle at 15° while testing blade count instead. Answer: D
5
Scientists pumped contaminated water with an initial dissolved copper ion (Cu²⁺) concentration of 50 mg/L through filter cartridges packed with activated carbon granules and measured the remaining Cu²⁺ concentration in the filtered water.
Table 1
Trial
Carbon mass (g)
Pump flow rate (mL/min)
Remaining Cu²⁺ (mg/L)
1
10
100
22
2
20
100
11
3
30
100
5
4
20
200
19
5
20
300
28
Based on Table 1, which combination of carbon mass and pump flow rate would modify the setup to produce filtered water with the lowest remaining Cu²⁺ concentration?
Check Carbon mass (Trials 1–3) and Pump flow rate (Trials 2, 4, and 5) separately to see which direction in each column pulls Remaining Cu²⁺ down.
Trace backward from the target (lowest remaining Cu²⁺): in Trials 1–3 (at 100 mL/min), increasing carbon mass from 10 g to 30 g lowers remaining Cu²⁺ from 22 to 5 mg/L, so move higher to 40 g (eliminating A and B). Next, check Trials 2, 4, and 5 (at 20 g) instead of guessing that faster pumping cleans better: raising flow rate from 100 to 300 mL/min pushes remaining Cu²⁺ up from 11 to 28 mg/L (eliminating D), so slow the flow rate down to 50 mL/min. Answer: C
6
To study how wind speed affects water loss through plant leaves, a student placed a fan at wind speeds of 0, 2, and 4 m/s in front of a cut leafy stem sealed into the top of a narrow water-filled glass tube. As water vapor escaped from the leaves into the room air, the student measured how far an air bubble inside the narrow tube moved in 30 minutes.
Without using a narrow bubble tube, which alternative setup could the student use to test this same relationship?
Keep wind speed (0, 2, and 4 m/s) and the leafy stem as the setup, then picture whether water vapor escaping from the leaves can actually leave the scale in each choice.
With the stem sealed into a water-filled flask by a snug stopper in open air, water vapor escaping from the leaves rises off the digital scale, so total mass drops over 30 minutes across wind speeds of 0, 2, and 4 m/s. Watch out for B: sealing the flask, plant, and fan inside an airtight jar traps all escaped water vapor right on the scale, so total mass never drops. C removes the plant stem entirely (measuring open-cup evaporation instead of leaf water loss), and D changes the knob from wind speed to leaf number. Answer: A
7
A student tested a digital thermometer by dipping its tip five times in a row into a well-stirred bath of pure ice and water known to have a true temperature of 0.0 °C. The five readings were:
+1.8 °C, +1.9 °C, +1.8 °C, +1.8 °C, +1.9 °C
Which statement correctly describes these five readings and identifies a modification that would fix the measurement flaw shown?
Compare the five readings to each other and then to 0.0 °C; next, ask what averaging 20 more dips of this same thermometer would still produce.
Five readings clustered tightly at +1.8 °C to +1.9 °C have almost no trial-to-trial wobble (precise), yet sit nearly 2 °C above the true 0.0 °C bath (not accurate), which eliminates A and B for swapping the two terms. Don't pick C: taking 20 more readings with the same off-center thermometer will still average around +1.8 °C, because averaging never removes a built-in offset; calibrating the thermometer to 0.0 °C fixes it. Answer: D
8
Students placed small LED bulbs of different power ratings in front of a digital light sensor in a dark room and recorded illuminance in lux. Whenever illuminance exceeds 2,000 lux, the sensor screen displays OVER instead of a number.
Table 1
Trial
Bulb power (W)
Distance from bulb to sensor (cm)
Sensor reading (lux)
1
2
20
450
2
4
20
900
3
8
20
1,800
4
4
40
225
5
12
20
OVER
6
16
20
OVER
Without replacing the light sensor, how should the students modify Trials 5 and 6 so they can obtain numerical readings and fairly compare the illuminance of the 12 W and 16 W bulbs?
Compare Trial 2 and Trial 4 to see how distance changes lux, and make sure distance stays locked between the 12 W and 16 W trials.
Comparing Trial 2 (20 cm → 900 lux) with Trial 4 (40 cm → 225 lux) shows that doubling a bulb's distance from 20 cm to 40 cm lowers lux to one-fourth, pulling 12 W (2,700 lux at 20 cm) down to 675 lux and 16 W (3,600 lux at 20 cm) down to 900 lux, well under the 2,000 lux limit (A moves them closer to 10 cm, misreading that inverse trend and keeping both at OVER). Watch out for C: testing 12 W at 30 cm and 16 W at 40 cm gets numbers on the screen, but changes distance between the two trials so the bulbs cannot be fairly compared. D treats a maxed-out sensor as a calibration or precision issue, which still leaves both bulbs above 2,000 lux at 20 cm. Answer: B